Experimental procedure
| Experimental method | SINGLE WAVELENGTH |
| Source type | SYNCHROTRON |
| Source details | APS BEAMLINE 24-ID-C |
| Synchrotron site | APS |
| Beamline | 24-ID-C |
| Temperature [K] | 100 |
| Detector technology | PIXEL |
| Collection date | 2012-10-25 |
| Detector | DECTRIS PILATUS 6M-F |
| Wavelength(s) | 0.9791 |
| Spacegroup name | P 21 21 21 |
| Unit cell lengths | 210.116, 448.512, 621.968 |
| Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
| Resolution | 34.990 - 3.340 |
| R-factor | 0.2386 |
| Rwork | 0.237 |
| R-free | 0.26680 |
| Structure solution method | MOLECULAR REPLACEMENT |
| RMSD bond length | 0.006 |
| RMSD bond angle | 1.015 |
| Refinement software | PHENIX |
Data quality characteristics
| Overall | |
| Low resolution limit [Å] | 35.000 |
| High resolution limit [Å] | 3.200 |
| Number of reflections | 923212 |
| <I/σ(I)> | 7.72 |
| Completeness [%] | 96.6 |
| Redundancy | 3.62 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 | VAPOR DIFFUSION, SITTING DROP | 7 | 293 | 5% PEG 20k, 5% PEG 550 MME, 100 mM TRIS-ACETATE, 200 mM KSCN, 10 mM MAGNESIUM CHLORIDE |