5VMC
Influenza hemagglutinin H1 mutant DH1 in complex with 6'SLN
Experimental procedure
| Experimental method | SINGLE WAVELENGTH |
| Source type | SYNCHROTRON |
| Source details | APS BEAMLINE 21-ID-F |
| Synchrotron site | APS |
| Beamline | 21-ID-F |
| Temperature [K] | 80 |
| Detector technology | CCD |
| Collection date | 2016-06-29 |
| Detector | MARMOSAIC 225 mm CCD |
| Wavelength(s) | 0.97872 |
| Spacegroup name | P 1 21 1 |
| Unit cell lengths | 95.680, 81.820, 121.460 |
| Unit cell angles | 90.00, 90.79, 90.00 |
Refinement procedure
| Resolution | 44.718 - 2.150 |
| R-factor | 0.1771 |
| Rwork | 0.176 |
| R-free | 0.20550 |
| Structure solution method | MOLECULAR REPLACEMENT |
| Starting model (for MR) | 2wrg |
| RMSD bond length | 0.006 |
| RMSD bond angle | 1.072 |
| Data reduction software | MOSFLM |
| Data scaling software | SCALA |
| Phasing software | PHENIX |
| Refinement software | PHENIX (1.9_1692) |
Data quality characteristics
| Overall | |
| Low resolution limit [Å] | 48.740 |
| High resolution limit [Å] | 2.150 |
| Number of reflections | 102164 |
| <I/σ(I)> | 9.4 |
| Completeness [%] | 100.0 |
| Redundancy | 4.3 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 | VAPOR DIFFUSION, HANGING DROP | 290 | 0.10 M NaF, 12% PEG3350 |