5VKF
RHCC in complex with Naphthalene
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | ROTATING ANODE |
Source details | RIGAKU MICROMAX-007 HF |
Temperature [K] | 100 |
Detector technology | IMAGE PLATE |
Collection date | 2012-10-31 |
Detector | RIGAKU RAXIS IV++ |
Wavelength(s) | 1.5418 |
Spacegroup name | P 31 2 1 |
Unit cell lengths | 110.359, 110.359, 70.827 |
Unit cell angles | 90.00, 90.00, 120.00 |
Refinement procedure
Resolution | 19.115 - 2.752 |
R-factor | 0.2032 |
Rwork | 0.199 |
R-free | 0.23920 |
Structure solution method | MOLECULAR REPLACEMENT |
Starting model (for MR) | 1fe6 |
RMSD bond length | 0.002 |
RMSD bond angle | 0.355 |
Data reduction software | XDS |
Data scaling software | Aimless |
Phasing software | PHASER |
Refinement software | PHENIX (1.11.1-2575_2575) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 19.120 | 2.900 |
High resolution limit [Å] | 2.750 | 2.750 |
Rmerge | 0.167 | 0.689 |
Rpim | 0.079 | 0.421 |
Number of reflections | 13074 | 1821 |
<I/σ(I)> | 7.2 | 2.4 |
Completeness [%] | 98.9 | 95.6 |
Redundancy | 5.1 | 5 |
CC(1/2) | 0.998 | 0.796 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, HANGING DROP | 8.5 | 277.15 | 1.5M Ammonium Sulfate, 0.1M Tris pH 8.5 |