5VCR
Alpha-1,6-mannosyl-glycoprotein 2-beta-N-acetylglucosaminyltransferase with bound uranium dioxide
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | APS BEAMLINE 22-ID |
Synchrotron site | APS |
Beamline | 22-ID |
Temperature [K] | 100 |
Detector technology | CCD |
Collection date | 2015-12-13 |
Detector | RAYONIX MX300-HS |
Wavelength(s) | 1.74 |
Spacegroup name | P 43 21 2 |
Unit cell lengths | 105.670, 105.670, 171.950 |
Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
Resolution | 56.397 - 1.992 |
R-factor | 0.1782 |
Rwork | 0.177 |
R-free | 0.20800 |
RMSD bond length | 0.017 |
RMSD bond angle | 1.456 |
Data reduction software | XDS |
Data scaling software | XDS |
Phasing software | PHENIX |
Refinement software | PHENIX ((1.10.1_2155: ???)) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 56.397 | |
High resolution limit [Å] | 1.992 | 1.992 |
Number of reflections | 126205 | |
<I/σ(I)> | 17.7 | |
Completeness [%] | 99.0 | |
Redundancy | 14.1 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, HANGING DROP | 293 | 1.4 M ammonium sulfate |