5UEV

BRD4_BD2_A-556343

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsAPS BEAMLINE 17-ID
Synchrotron siteAPS
Beamline17-ID
Temperature [K]100
Detector technologyPIXEL
Collection date2010-08-09
DetectorDECTRIS PILATUS3 S 6M
Wavelength(s)1.0
Spacegroup nameP 21 21 2
Unit cell lengths56.426, 73.514, 33.681
Unit cell angles90.00, 90.00, 90.00
Refinement procedure
Resolution36.760 - 1.940
R-factor0.201
Rwork0.200
R-free0.23700
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)Apo BRD4_BD2
RMSD bond length0.010
RMSD bond angle0.920
Data reduction softwareXDS (2.11.7)
Data scaling softwareSCALA
Refinement softwareBUSTER (2.11.7)
Data quality characteristics
 Overall
Low resolution limit [Å]73.500
High resolution limit [Å]1.930
Number of reflections10978
<I/σ(I)>9.5
Completeness [%]99.8
Redundancy5.9
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION277Protein Buffer : 10 mM HEPES PH 7.5 100 mM NaCl 5 mM DTT Crystallization : 15 % (v/v) Ethanol Tris PH 7.0