5TWP
Pre-catalytic ternary complex of human Polymerase Mu with incoming nonhydrolyzable UMPNPP
Experimental procedure
| Experimental method | SINGLE WAVELENGTH |
| Source type | ROTATING ANODE |
| Source details | RIGAKU MICROMAX-007 HF |
| Temperature [K] | 100 |
| Detector technology | CCD |
| Collection date | 2012-11-09 |
| Detector | RIGAKU SATURN 92 |
| Wavelength(s) | 1.5418 |
| Spacegroup name | P 21 21 21 |
| Unit cell lengths | 59.937, 68.696, 110.119 |
| Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
| Resolution | 21.143 - 2.001 |
| R-factor | 0.1878 |
| Rwork | 0.185 |
| R-free | 0.23790 |
| Structure solution method | MOLECULAR REPLACEMENT |
| Starting model (for MR) | 4m04 |
| RMSD bond length | 0.008 |
| RMSD bond angle | 1.057 |
| Data reduction software | HKL-3000 |
| Data scaling software | HKL-3000 |
| Phasing software | PHASER |
| Refinement software | PHENIX ((1.10.1_2155)) |
Data quality characteristics
| Overall | Outer shell | |
| Low resolution limit [Å] | 50.000 | 2.070 |
| High resolution limit [Å] | 2.000 | 2.000 |
| Rmerge | 0.495 | |
| Number of reflections | 31042 | |
| <I/σ(I)> | 14.37 | 2.71 |
| Completeness [%] | 98.8 | 94.5 |
| Redundancy | 6.1 | 4 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 | VAPOR DIFFUSION, SITTING DROP | 7.5 | 294 | 95mM HEPES pH 7.5, 19% PEG4K |