5TCL

Thaumatin from 4.96 A wavelength data collection

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsDIAMOND BEAMLINE I23
Synchrotron siteDiamond
BeamlineI23
Temperature [K]43
Detector technologyPIXEL
Collection date2016-03-04
DetectorDECTRIS PILATUS 12M
Wavelength(s)4.95937
Spacegroup nameP 41 21 2
Unit cell lengths57.769, 57.769, 150.512
Unit cell angles90.00, 90.00, 90.00
Refinement procedure
Resolution53.933 - 3.201
R-factor0.2032
Rwork0.199
R-free0.24570
Structure solution methodSAD
Starting model (for MR)4zg3
RMSD bond length0.003
RMSD bond angle0.523
Data reduction softwareXDS (May 1, 2016)
Data scaling softwareXDS (May 1, 2016)
Phasing softwareSHARP (2.8.5)
Refinement softwarePHENIX (1.11.1_2575)
Data quality characteristics
 OverallInner shellOuter shell
Low resolution limit [Å]150.6083.390
High resolution limit [Å]3.2009.4703.200
Rmerge0.0770.0550.141
Number of reflections7361
<I/σ(I)>21.3844.249.35
Completeness [%]91.510075.4
Redundancy9.30714.9165.781
CC(1/2)0.9960.9990.986
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, HANGING DROP6.82920.7 M K/Na Tartrate, 0.05 M ADA pH 6.8, 20% (v/v) glycerol

219869