Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

5T3S

HIV gp140 trimer MD39-10MUTA in complex with Fabs PGT124 and 35022

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsAPS BEAMLINE 23-ID-D
Synchrotron siteAPS
Beamline23-ID-D
Temperature [K]100
Detector technologyPIXEL
Collection date2016-02-14
DetectorDECTRIS PILATUS 6M
Wavelength(s)1.03322
Spacegroup nameP 63
Unit cell lengths127.915, 127.915, 313.887
Unit cell angles90.00, 90.00, 120.00
Refinement procedure
Resolution50.010 - 4.500
R-factor0.27158
Rwork0.270
R-free0.30877
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)5cez
RMSD bond length0.011
RMSD bond angle1.513
Data reduction softwareDENZO
Data scaling softwareSCALEPACK
Phasing softwarePHASER
Refinement softwareREFMAC (5.8.0155)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]50.0104.580
High resolution limit [Å]4.5004.500
Rmerge0.2131.000
Number of reflections17067
<I/σ(I)>4.751.1
Completeness [%]98.498.9
Redundancy4.34.4
CC(1/2)0.7600.630
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, SITTING DROP4.12775% Peg6000 0.1M citric acid

219869

PDB entries from 2024-05-15

PDB statisticsPDBj update infoContact PDBjnumon