Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

5RE2

PanDDA analysis group deposition -- Endothiapepsin ground state model 59

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsMAX IV BEAMLINE BioMAX
Synchrotron siteMAX IV
BeamlineBioMAX
Temperature [K]100
Detector technologyPIXEL
Collection date2019-03-30
DetectorDECTRIS EIGER X 16M
Wavelength(s)0.827
Spacegroup nameP 1 21 1
Unit cell lengths45.292, 72.849, 52.463
Unit cell angles90.00, 109.22, 90.00
Refinement procedure
Resolution42.800 - 1.000
R-factor0.1843
Rwork0.184
R-free0.18432
Structure solution methodFOURIER SYNTHESIS
RMSD bond length0.018
RMSD bond angle1.898
Data reduction softwareXDS
Data scaling softwareXSCALE
Phasing softwareREFMAC (5.8.0238)
Refinement softwareREFMAC (5.8.0238)
Data quality characteristics
 OverallInner shellOuter shell
Low resolution limit [Å]42.80050.0001.050
High resolution limit [Å]1.0002.9700.990
Rmerge0.0600.0311.613
Rmeas0.0660.0341.788
Total number of observations1064806
Number of reflections162288663522870
<I/σ(I)>13.7846.270.93
Completeness [%]96.10.9780.797
Redundancy6.2295.574.21
CC(1/2)0.9990.9990.388
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, SITTING DROP4.62900.1 M ammonium acetate, 0.1 M sodium acetate, 24-30% PEG 4000

219869

PDB entries from 2024-05-15

PDB statisticsPDBj update infoContact PDBjnumon