Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

5RCZ

PanDDA analysis group deposition -- Endothiapepsin ground state model 21

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsMAX IV BEAMLINE BioMAX
Synchrotron siteMAX IV
BeamlineBioMAX
Temperature [K]100
Detector technologyPIXEL
Collection date2019-03-30
DetectorDECTRIS EIGER X 16M
Wavelength(s)0.827
Spacegroup nameP 1 21 1
Unit cell lengths45.114, 73.035, 52.353
Unit cell angles90.00, 109.07, 90.00
Refinement procedure
Resolution49.530 - 1.040
R-factor0.1566
Rwork0.156
R-free0.15656
Structure solution methodFOURIER SYNTHESIS
RMSD bond length0.019
RMSD bond angle1.926
Data reduction softwareXDS
Data scaling softwareXSCALE
Phasing softwareREFMAC (5.8.0238)
Refinement softwareREFMAC (5.8.0238)
Data quality characteristics
 OverallInner shellOuter shell
Low resolution limit [Å]49.53050.0001.100
High resolution limit [Å]1.0403.1101.040
Rmerge0.0500.0301.499
Rmeas0.0540.0331.621
Total number of observations1029390
Number of reflections142952579323210
<I/σ(I)>1554.771.09
Completeness [%]97.20.980.928
Redundancy6.8376.566.28
CC(1/2)0.9990.9990.508
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, SITTING DROP4.62900.1 M ammonium acetate, 0.1 M sodium acetate, 24-30% PEG 4000