Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

5RCX

PanDDA analysis group deposition -- Endothiapepsin ground state model 19

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsMAX IV BEAMLINE BioMAX
Synchrotron siteMAX IV
BeamlineBioMAX
Temperature [K]100
Detector technologyPIXEL
Collection date2019-03-30
DetectorDECTRIS EIGER X 16M
Wavelength(s)0.827
Spacegroup nameP 1 21 1
Unit cell lengths45.212, 72.935, 52.469
Unit cell angles90.00, 109.13, 90.00
Refinement procedure
Resolution49.620 - 1.040
R-factor0.1508
Rwork0.150
R-free0.15082
Structure solution methodFOURIER SYNTHESIS
RMSD bond length0.019
RMSD bond angle1.927
Data reduction softwareXDS
Data scaling softwareXSCALE
Phasing softwareREFMAC (5.8.0238)
Refinement softwareREFMAC (5.8.0238)
Data quality characteristics
 OverallInner shellOuter shell
Low resolution limit [Å]49.62050.0001.100
High resolution limit [Å]1.0403.1101.040
Rmerge0.0510.0370.839
Rmeas0.0550.0400.910
Total number of observations1044525
Number of reflections146152575124600
<I/σ(I)>15.5848.541.84
Completeness [%]99.60.9760.987
Redundancy6.7916.456.53
CC(1/2)0.9990.9980.772
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, SITTING DROP4.62900.1 M ammonium acetate, 0.1 M sodium acetate, 24-30% PEG 4000

219869