Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

5RCS

PanDDA analysis group deposition -- Endothiapepsin ground state model 14

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsMAX IV BEAMLINE BioMAX
Synchrotron siteMAX IV
BeamlineBioMAX
Temperature [K]100
Detector technologyPIXEL
Collection date2019-03-30
DetectorDECTRIS EIGER X 16M
Wavelength(s)0.827
Spacegroup nameP 1 21 1
Unit cell lengths45.170, 72.952, 52.420
Unit cell angles90.00, 109.11, 90.00
Refinement procedure
Resolution42.720 - 0.970
R-factor0.1795
Rwork0.179
R-free0.17954
Structure solution methodFOURIER SYNTHESIS
RMSD bond length0.017
RMSD bond angle1.914
Data reduction softwareXDS
Data scaling softwareXSCALE
Phasing softwareREFMAC (5.8.0238)
Refinement softwareREFMAC (5.8.0238)
Data quality characteristics
 OverallInner shellOuter shell
Low resolution limit [Å]42.72050.0001.030
High resolution limit [Å]0.9702.9000.970
Rmerge0.0870.0532.272
Rmeas0.0940.0582.489
Total number of observations1179212
Number of reflections164738716719556
<I/σ(I)>10.3734.990.62
Completeness [%]91.00.9880.634
Redundancy6.7896.743.74
CC(1/2)0.9980.9960.229
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, SITTING DROP4.62900.1 M ammonium acetate, 0.1 M sodium acetate, 24-30% PEG 4000