5QAV

OXA-48 IN COMPLEX WITH COMPOUND 26b

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsESRF BEAMLINE ID23-1
Synchrotron siteESRF
BeamlineID23-1
Temperature [K]100
Detector technologyPIXEL
Collection date2016-09-30
DetectorDECTRIS PILATUS 6M
Wavelength(s)0.97625
Spacegroup nameP 21 21 21
Unit cell lengths90.070, 108.424, 124.555
Unit cell angles90.00, 90.00, 90.00
Refinement procedure
Resolution40.890 - 1.720
Rwork0.179
R-free0.20540
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR): 5dtk
RMSD bond length0.005
RMSD bond angle0.727
Data reduction softwareXDS
Data scaling softwareAimless
Phasing softwarePHASER
Refinement softwarePHENIX (1.11.1_2575)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]40.8901.780
High resolution limit [Å]1.7201.720
Rmerge0.0610.670
Rmeas0.0700.770
Number of reflections50045
<I/σ(I)>11.271.8
Completeness [%]98.3
Redundancy4.34.1
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, HANGING DROP7.52980.1 M HEPES pH 7.5, 8-11% PEG 8000 and 4-8% 1-butanol