Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

5QAL

OXA-48 IN COMPLEX WITH COMPOUND 11b

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsESRF BEAMLINE ID23-2
Synchrotron siteESRF
BeamlineID23-2
Temperature [K]100
Detector technologyPIXEL
Collection date2015-12-01
DetectorDECTRIS PILATUS 6M
Wavelength(s)0.8726
Spacegroup nameP 21 21 21
Unit cell lengths85.024, 104.043, 126.849
Unit cell angles90.00, 90.00, 90.00
Refinement procedure
Resolution45.680 - 1.950
Rwork0.170
R-free0.19470
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR): 5dtk
RMSD bond length0.005
RMSD bond angle0.736
Data reduction softwareXDS
Data scaling softwareAimless
Phasing softwarePHASER
Refinement softwarePHENIX (1.11.1_2575)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]45.6802.020
High resolution limit [Å]1.9501.950
Rmerge0.1500.764
Rmeas0.1700.860
Number of reflections39564
<I/σ(I)>7.672.1
Completeness [%]99.3
Redundancy4.74.9
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, HANGING DROP7.52980.1 M HEPES pH 7.5, 8-11% PEG 8000 and 4-8% 1-butanol

219869

PDB entries from 2024-05-15

PDB statisticsPDBj update infoContact PDBjnumon