Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

5QA9

OXA-48 IN COMPLEX WITH COMPOUND 5

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsBESSY BEAMLINE 14.1
Synchrotron siteBESSY
Beamline14.1
Temperature [K]100
Detector technologyPIXEL
Collection date2016-01-13
DetectorDECTRIS PILATUS 6M
Wavelength(s)0.91841
Spacegroup nameP 21 21 21
Unit cell lengths88.981, 108.447, 124.139
Unit cell angles90.00, 90.00, 90.00
Refinement procedure
Resolution43.380 - 1.900
Rwork0.190
R-free0.22990
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR): 5dtk
RMSD bond length0.003
RMSD bond angle0.601
Data reduction softwareXDS
Data scaling softwareAimless
Phasing softwarePHASER
Refinement softwarePHENIX (1.11.1_2575)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]43.3801.970
High resolution limit [Å]1.9001.900
Rmerge0.1340.762
Rmeas0.1500.860
Number of reflections41687
<I/σ(I)>8.632.2
Completeness [%]98.9
Redundancy4.44.5
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, HANGING DROP7.52980.1 M HEPES pH 7.5, 8-11% PEG 8000 and 4-8% 1-butanol

219869

PDB entries from 2024-05-15

PDB statisticsPDBj update infoContact PDBjnumon