5P4D
Automated refinement of diffraction data obtained from an endothiapepsin crystal treated with fragment 202
Experimental procedure
| Experimental method | SINGLE WAVELENGTH |
| Source type | SYNCHROTRON |
| Source details | BESSY BEAMLINE 14.1 |
| Synchrotron site | BESSY |
| Beamline | 14.1 |
| Temperature [K] | 100 |
| Detector technology | PIXEL |
| Collection date | 2014-06-04 |
| Detector | DECTRIS PILATUS 6M |
| Wavelength(s) | 0.918409 |
| Spacegroup name | P 1 21 1 |
| Unit cell lengths | 45.220, 73.108, 52.837 |
| Unit cell angles | 90.00, 109.30, 90.00 |
Refinement procedure
| Resolution | 28.152 - 1.247 |
| R-factor | 0.131 |
| Rwork | 0.130 |
| R-free | 0.15290 |
| Structure solution method | MOLECULAR REPLACEMENT |
| Starting model (for MR) | 4y5l |
| RMSD bond length | 0.006 |
| RMSD bond angle | 1.168 |
| Data reduction software | XDS |
| Data scaling software | XDS |
| Phasing software | PHASER (2.5.7) |
| Refinement software | PHENIX |
Data quality characteristics
| Overall | Inner shell | Outer shell | |
| Low resolution limit [Å] | 42.678 | 1.320 | |
| High resolution limit [Å] | 1.250 | 3.730 | 1.250 |
| Rmerge | 0.049 | 0.019 | 0.494 |
| Rmeas | 0.058 | 0.022 | 0.578 |
| Total number of observations | 333069 | ||
| Number of reflections | 89600 | 3437 | 14172 |
| <I/σ(I)> | 14.72 | 57.92 | 2.28 |
| Completeness [%] | 99.3 | 99 | 97.2 |
| Redundancy | 3.717 | ||
| CC(1/2) | 0.999 | 0.999 | 0.770 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 | VAPOR DIFFUSION, SITTING DROP | 4.6 | 290 | 0.1 M ammonium acetate, 0.1 M sodium acetate, 24-30% PEG 4000; crystal obtained by streak-seeding and soaked with 90 mM of fragment 202 with the SMILES code COC1=C(C=CC=N1)C(O)=O |