5P3P
Automated refinement of diffraction data obtained from an endothiapepsin crystal treated with fragment 178
Experimental procedure
| Experimental method | SINGLE WAVELENGTH |
| Source type | SYNCHROTRON |
| Source details | BESSY BEAMLINE 14.1 |
| Synchrotron site | BESSY |
| Beamline | 14.1 |
| Temperature [K] | 100 |
| Detector technology | PIXEL |
| Collection date | 2013-04-04 |
| Detector | DECTRIS PILATUS 6M |
| Wavelength(s) | 0.918409 |
| Spacegroup name | P 21 21 21 |
| Unit cell lengths | 45.046, 72.613, 103.592 |
| Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
| Resolution | 42.167 - 1.459 |
| R-factor | 0.1415 |
| Rwork | 0.140 |
| R-free | 0.17080 |
| Structure solution method | MOLECULAR REPLACEMENT |
| Starting model (for MR) | 4y5l |
| RMSD bond length | 0.007 |
| RMSD bond angle | 1.159 |
| Data reduction software | XDS |
| Data scaling software | XDS |
| Phasing software | PHASER (2.5.7) |
| Refinement software | PHENIX |
Data quality characteristics
| Overall | Inner shell | Outer shell | |
| Low resolution limit [Å] | 45.046 | 1.550 | |
| High resolution limit [Å] | 1.460 | 4.350 | 1.460 |
| Rmerge | 0.060 | 0.024 | 0.502 |
| Rmeas | 0.064 | 0.026 | 0.541 |
| Total number of observations | 418646 | ||
| Number of reflections | 59825 | 2446 | 9456 |
| <I/σ(I)> | 19.89 | 65.3 | 3.75 |
| Completeness [%] | 99.7 | 99.5 | 98.8 |
| Redundancy | 6.997 | ||
| CC(1/2) | 0.999 | 0.999 | 0.879 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 | VAPOR DIFFUSION, SITTING DROP | 4.6 | 290 | 0.1 M ammonium acetate, 0.1 M sodium acetate, 24-30% PEG 4000; crystal obtained by streak-seeding and soaked with 90 mM of fragment 178 with the SMILES code CC1CCN(CCCNS(=O)(=O)C2=CC=CS2)CC1 |