5OYL
VSV G CR2
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | SOLEIL BEAMLINE PROXIMA 1 |
Synchrotron site | SOLEIL |
Beamline | PROXIMA 1 |
Temperature [K] | 100 |
Detector technology | PIXEL |
Collection date | 2015-07-24 |
Detector | DECTRIS PILATUS 6M |
Wavelength(s) | 0.978570 |
Spacegroup name | H 3 2 |
Unit cell lengths | 90.040, 90.040, 515.780 |
Unit cell angles | 90.00, 90.00, 120.00 |
Refinement procedure
Resolution | 29.979 - 2.250 |
R-factor | 0.1899 |
Rwork | 0.188 |
R-free | 0.22380 |
Structure solution method | MOLECULAR REPLACEMENT |
Starting model (for MR) | 5i2s |
Data reduction software | XDS |
Data scaling software | XSCALE |
Phasing software | MOLREP |
Refinement software | REFMAC |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 49.680 | 2.300 |
High resolution limit [Å] | 2.240 | 2.240 |
Rmerge | 0.184 | |
Rmeas | 0.203 | |
Rpim | 0.061 | 1.741 |
Number of reflections | 39498 | 2829 |
<I/σ(I)> | 8.7 | 0.6 |
Completeness [%] | 99.9 | 98.3 |
Redundancy | 11 | 10.9 |
CC(1/2) | 0.998 | 0.494 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, HANGING DROP | 293 | 29% PEG 3000, 100 mM Tris-HCl pH 8.5, 200 mM LiSO4 |