Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

5OU1

M. thermoresistible IMPDH in complex with IMP and Compound 1 (7759844)

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsDIAMOND BEAMLINE I04
Synchrotron siteDiamond
BeamlineI04
Temperature [K]77
Detector technologyPIXEL
Collection date2015-12-02
DetectorDECTRIS PILATUS 6M-F
Wavelength(s)0.98
Spacegroup nameI 4
Unit cell lengths88.720, 88.720, 84.780
Unit cell angles90.00, 90.00, 90.00
Refinement procedure
Resolution44.360 - 1.780
Structure solution methodMOLECULAR REPLACEMENT
Data reduction softwareXDS
Data scaling softwareAimless
Phasing softwarePHENIX
Refinement softwarePHENIX
Data quality characteristics
 Overall
Low resolution limit [Å]44.360
High resolution limit [Å]1.780
Number of reflections31464
<I/σ(I)>10.95
Completeness [%]100.0
Redundancy2
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, HANGING DROP292100mM sodium acetate pH 5.5, 200mM calcium chloride, 8-14% iso-propanol

219869

PDB entries from 2024-05-15

PDB statisticsPDBj update infoContact PDBjnumon