Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

5OO0

Cdk2(WT) covalent adduct with D28 at C177

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsDIAMOND BEAMLINE I04
Synchrotron siteDiamond
BeamlineI04
Temperature [K]100
Detector technologyCCD
Collection date2017-05-20
DetectorADSC QUANTUM 315
Wavelength(s)0.9795
Spacegroup nameP 21 21 21
Unit cell lengths53.513, 71.024, 72.152
Unit cell angles90.00, 90.00, 90.00
Refinement procedure
Resolution42.000 - 1.600
R-factor0.17299
Rwork0.172
R-free0.20035
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)4ek3
RMSD bond length0.027
RMSD bond angle2.437
Data reduction softwarexia2
Data scaling softwarexia2
Phasing softwarePHASER
Refinement softwareREFMAC (5.8.0158)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]50.6201.630
High resolution limit [Å]1.6001.600
Rmerge0.0180.071
Number of reflections365681749
<I/σ(I)>21.27.5
Completeness [%]99.298
Redundancy1.91.9
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, HANGING DROP29415% w/v Jeffamine ED-2003, 50 mM HEPES, 50 mM sodium/potassium phosphate

219869