Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

5OLS

Rhamnogalacturonan lyase

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsDIAMOND BEAMLINE I04
Synchrotron siteDiamond
BeamlineI04
Temperature [K]100
Detector technologyPIXEL
Collection date2015-10-16
DetectorDECTRIS PILATUS 6M
Wavelength(s)0.97912
Spacegroup nameP 21 21 21
Unit cell lengths45.420, 76.600, 122.760
Unit cell angles90.00, 90.00, 90.00
Refinement procedure
Resolution61.380 - 2.200
R-factor0.23506
Rwork0.233
R-free0.27105
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)5olq
RMSD bond length0.008
RMSD bond angle1.381
Data reduction softwarexia2
Data scaling softwareXDS
Phasing softwareMOLREP
Refinement softwareREFMAC (5.8.0158)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]61.7002.260
High resolution limit [Å]2.2002.200
Number of reflections224861650
<I/σ(I)>13.41.6
Completeness [%]99.899.5
Redundancy6.97.2
CC(1/2)0.9980.553
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, SITTING DROP293200 mM potassium chloride and 20% PEG 3350

219869

PDB entries from 2024-05-15

PDB statisticsPDBj update infoContact PDBjnumon