Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

5MNP

Cationic trypsin in complex with N-amidinopiperidine (at 295 K)

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsPETRA III, EMBL c/o DESY BEAMLINE P14 (MX2)
Synchrotron sitePETRA III, EMBL c/o DESY
BeamlineP14 (MX2)
Temperature [K]295
Detector technologyPIXEL
Collection date2015-06-10
DetectorDECTRIS PILATUS 6M
Wavelength(s)0.7749
Spacegroup nameP 21 21 21
Unit cell lengths54.921, 58.623, 67.731
Unit cell angles90.00, 90.00, 90.00
Refinement procedure
Resolution19.671 - 1.010
R-factor0.0901
Rwork0.089
R-free0.10250
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)4i8h
RMSD bond length0.008
RMSD bond angle1.134
Data reduction softwareXDS
Data scaling softwareXDS
Phasing softwarePHASER
Refinement softwarePHENIX ((1.10.1_2155))
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]42.6591.070
High resolution limit [Å]1.0101.010
Rmerge0.0410.545
Number of reflections107988
<I/σ(I)>26.884.2
Completeness [%]93.892.2
Redundancy9.2849.034
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, SITTING DROP7.52770.2 M ammonium sulfate, 0.1 M Hepes pH 7.5, 13.7% (w/v) PEG 8000

219869

PDB entries from 2024-05-15

PDB statisticsPDBj update infoContact PDBjnumon