5MHR
T3D reovirus sigma1 complexed with 9BG5 Fab fragments
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | SLS BEAMLINE X06SA |
Synchrotron site | SLS |
Beamline | X06SA |
Temperature [K] | 100 |
Detector technology | PIXEL |
Collection date | 2015-03-22 |
Detector | DECTRIS PILATUS 2M-F |
Wavelength(s) | 1.0 |
Spacegroup name | P 1 |
Unit cell lengths | 103.163, 109.306, 131.699 |
Unit cell angles | 103.13, 113.56, 103.48 |
Refinement procedure
Resolution | 49.050 - 3.000 |
R-factor | 0.214 |
Rwork | 0.212 |
R-free | 0.24700 |
Structure solution method | MOLECULAR REPLACEMENT |
Starting model (for MR) | 2OJ5 AND 1FIG |
RMSD bond length | 0.004 |
RMSD bond angle | 0.661 |
Data reduction software | XDS |
Data scaling software | XDS |
Phasing software | PHASER |
Refinement software | PHENIX ((1.10.1_2155: ???)) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 49.045 | 3.080 |
High resolution limit [Å] | 3.000 | 3.000 |
Number of reflections | 94667 | |
<I/σ(I)> | 13.08 | 1.89 |
Completeness [%] | 98.5 | 98.4 |
Redundancy | 3.6 | 3.7 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, HANGING DROP | 7 | 277 | 11% (w/v) PEG8000, 0.1 M Tris pH 7.0, 0.2 M magnesium chloride |