5LD0
Chimeric GST
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | EMBL/DESY, HAMBURG BEAMLINE X13 |
Synchrotron site | EMBL/DESY, HAMBURG |
Beamline | X13 |
Temperature [K] | 100 |
Detector technology | CCD |
Collection date | 2008-10-11 |
Detector | MARRESEARCH |
Wavelength(s) | 0.8120 |
Spacegroup name | C 2 2 21 |
Unit cell lengths | 58.500, 90.900, 82.900 |
Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
Resolution | 19.277 - 1.600 |
R-factor | 0.1742 |
Rwork | 0.173 |
R-free | 0.20070 |
Structure solution method | MOLECULAR REPLACEMENT |
Starting model (for MR) | 1pkz |
RMSD bond length | 0.006 |
RMSD bond angle | 0.898 |
Data reduction software | XDS |
Data scaling software | XSCALE |
Phasing software | PHASER |
Refinement software | PHENIX ((1.10_2155: ???)) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 20.000 | 1.640 |
High resolution limit [Å] | 1.600 | 1.600 |
Number of reflections | 28561 | |
<I/σ(I)> | 16.95 | 1.4 |
Completeness [%] | 96.6 | 81.3 |
Redundancy | 3.7 | 3 |
CC(1/2) | 0.497 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, HANGING DROP | 289 | Sodium formate 0.15 M, PEG 4000 15% (w/v) |