5L22
PrtD T1SS ABC transporter
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | APS BEAMLINE 23-ID-D |
Synchrotron site | APS |
Beamline | 23-ID-D |
Temperature [K] | 100 |
Detector technology | PIXEL |
Collection date | 2015-04-18 |
Detector | DECTRIS PILATUS3 S 6M |
Wavelength(s) | 1.0007 |
Spacegroup name | C 1 2 1 |
Unit cell lengths | 118.672, 97.938, 179.823 |
Unit cell angles | 90.00, 100.47, 90.00 |
Refinement procedure
Resolution | 33.536 - 3.150 |
R-factor | 0.226 |
Rwork | 0.223 |
R-free | 0.27580 |
Structure solution method | SAD |
RMSD bond length | 0.003 |
RMSD bond angle | 0.736 |
Data reduction software | XDS |
Data scaling software | Aimless |
Phasing software | SHELXCD |
Refinement software | PHENIX (1.8.4_1496) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 34.300 | 3.270 |
High resolution limit [Å] | 3.120 | 3.120 |
Rmerge | 0.107 | 0.809 |
Number of reflections | 35413 | |
<I/σ(I)> | 8.3 | |
Completeness [%] | 97.4 | |
Redundancy | 4 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, SITTING DROP | 297 | 16-21% PEG 1000, 100-400 mM (NH4)2SO4, with 10 mM MES pH 6.5 |