5KS2
RAWV_CTD (Helix form) of 16S/23S 2'-O-methyltransferase TlyA
Experimental procedure
| Experimental method | SINGLE WAVELENGTH |
| Source type | SYNCHROTRON |
| Source details | APS BEAMLINE 22-ID |
| Synchrotron site | APS |
| Beamline | 22-ID |
| Temperature [K] | 80 |
| Detector technology | CCD |
| Collection date | 2016-02-21 |
| Detector | RAYONIX MX300-HS |
| Wavelength(s) | 1.000 |
| Spacegroup name | P 43 21 2 |
| Unit cell lengths | 67.852, 67.852, 79.458 |
| Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
| Resolution | 51.600 - 2.180 |
| Rwork | 0.193 |
| R-free | 0.24890 |
| Structure solution method | MOLECULAR REPLACEMENT |
| Starting model (for MR) | 5eov |
| Data reduction software | HKL-2000 |
| Data scaling software | HKL-2000 |
| Phasing software | PHASER |
| Refinement software | REFMAC (5.8.0151) |
Data quality characteristics
| Overall | Outer shell | |
| Low resolution limit [Å] | 51.600 | 2.240 |
| High resolution limit [Å] | 2.180 | 2.180 |
| Rmerge | 0.319 | 0.984 |
| Number of reflections | 10172 | |
| <I/σ(I)> | 19.2 | 4.7 |
| Completeness [%] | 99.9 | 99.9 |
| Redundancy | 13.2 | 5.6 |
| CC(1/2) | 0.558 | 0.588 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 | VAPOR DIFFUSION, HANGING DROP | 7.5 | 293 | 0.3 M Hepes pH 7.5 2.8M NaCl |