Loading
PDBj
MenuPDBj@FacebookPDBj@X(formerly Twitter)PDBj@BlueSkyPDBj@YouTubewwPDB FoundationwwPDBDonate
RCSB PDBPDBeBMRBAdv. SearchSearch help

5KIY

p97 ND1-A232E in complex with VIMP

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsAPS BEAMLINE 22-ID
Synchrotron siteAPS
Beamline22-ID
Temperature [K]100
Detector technologyCCD
Collection date2015-04-01
DetectorRAYONIX MX300-HS
Wavelength(s)1
Spacegroup nameP 6 2 2
Unit cell lengths144.998, 144.998, 119.817
Unit cell angles90.00, 90.00, 120.00
Refinement procedure
Resolution125.570 - 2.790
R-factor0.19609
Rwork0.193
R-free0.25649
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)4ko8
RMSD bond length0.017
RMSD bond angle1.928
Data reduction softwareDENZO
Data scaling softwareSCALEPACK
Phasing softwareMOLREP
Refinement softwareREFMAC (5.8.0158)
Data quality characteristics
 Overall
Low resolution limit [Å]50.000
High resolution limit [Å]2.790
Number of reflections18688
<I/σ(I)>22.8
Completeness [%]98.3
Redundancy4
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, SITTING DROP2880.1 M Tris, pH 8, 6-7 % ethanol, 100 mM NaCl, 3.6-4.2 % MPD

229380

PDB entries from 2024-12-25

PDB statisticsPDBj update infoContact PDBjnumon