5JEL
Phosphorylated TRIF in complex with IRF-3
Experimental procedure
| Experimental method | SINGLE WAVELENGTH |
| Source type | SYNCHROTRON |
| Source details | ALS BEAMLINE 5.0.1 |
| Synchrotron site | ALS |
| Beamline | 5.0.1 |
| Temperature [K] | 120 |
| Detector technology | CCD |
| Collection date | 2015-05-28 |
| Detector | ADSC QUANTUM 315r |
| Wavelength(s) | 1.0 |
| Spacegroup name | P 32 2 1 |
| Unit cell lengths | 72.811, 72.811, 127.602 |
| Unit cell angles | 90.00, 90.00, 120.00 |
Refinement procedure
| Resolution | 44.848 - 1.600 |
| R-factor | 0.1687 |
| Rwork | 0.168 |
| R-free | 0.18710 |
| RMSD bond length | 0.006 |
| RMSD bond angle | 1.039 |
| Data reduction software | DENZO |
| Data scaling software | SCALEPACK |
| Phasing software | PHASER |
| Refinement software | PHENIX (1.9_1692) |
Data quality characteristics
| Overall | |
| Low resolution limit [Å] | 44.848 |
| High resolution limit [Å] | 1.600 |
| Number of reflections | 52282 |
| <I/σ(I)> | 45.2 |
| Completeness [%] | 99.8 |
| Redundancy | 11.9 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 | VAPOR DIFFUSION, HANGING DROP | 277 | 0.1M NaAc pH 4.6, 2.0M NaCl |