5JEL
Phosphorylated TRIF in complex with IRF-3
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | ALS BEAMLINE 5.0.1 |
Synchrotron site | ALS |
Beamline | 5.0.1 |
Temperature [K] | 120 |
Detector technology | CCD |
Collection date | 2015-05-28 |
Detector | ADSC QUANTUM 315r |
Wavelength(s) | 1.0 |
Spacegroup name | P 32 2 1 |
Unit cell lengths | 72.811, 72.811, 127.602 |
Unit cell angles | 90.00, 90.00, 120.00 |
Refinement procedure
Resolution | 44.848 - 1.600 |
R-factor | 0.1687 |
Rwork | 0.168 |
R-free | 0.18710 |
RMSD bond length | 0.006 |
RMSD bond angle | 1.039 |
Data reduction software | DENZO |
Data scaling software | SCALEPACK |
Phasing software | PHASER |
Refinement software | PHENIX (1.9_1692) |
Data quality characteristics
Overall | |
Low resolution limit [Å] | 44.848 |
High resolution limit [Å] | 1.600 |
Number of reflections | 52282 |
<I/σ(I)> | 45.2 |
Completeness [%] | 99.8 |
Redundancy | 11.9 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, HANGING DROP | 277 | 0.1M NaAc pH 4.6, 2.0M NaCl |