5IV8
The LPS Transporter LptDE from Klebsiella pneumoniae, core complex
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | APS BEAMLINE 22-ID |
Synchrotron site | APS |
Beamline | 22-ID |
Temperature [K] | 90 |
Detector technology | CCD |
Collection date | 2013-05-10 |
Detector | MARMOSAIC 300 mm CCD |
Wavelength(s) | 1.00000 |
Spacegroup name | P 1 21 1 |
Unit cell lengths | 75.020, 173.050, 84.757 |
Unit cell angles | 90.00, 111.26, 90.00 |
Refinement procedure
Resolution | 41.414 - 2.938 |
R-factor | 0.2378 |
Rwork | 0.235 |
R-free | 0.28390 |
Structure solution method | MOLECULAR REPLACEMENT |
Starting model (for MR) | 4q35 |
RMSD bond length | 0.002 |
RMSD bond angle | 0.488 |
Data reduction software | HKL-2000 |
Data scaling software | HKL-2000 |
Phasing software | PHASER |
Refinement software | PHENIX ((1.10_2155: ???)) |
Data quality characteristics
Overall | |
Low resolution limit [Å] | 46.580 |
High resolution limit [Å] | 2.938 |
Number of reflections | 41834 |
<I/σ(I)> | 16.6 |
Completeness [%] | 97.4 |
Redundancy | 4 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, HANGING DROP | 8 | 294 | 22% PEG4K, 200mM ammonium phosphate |