5ILM
H64A sperm whale myoglobin with a Fe-chlorophenyl moiety
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | ROTATING ANODE |
Source details | RIGAKU MICROMAX-007 HF |
Temperature [K] | 100 |
Detector technology | PIXEL |
Collection date | 2014-06-19 |
Detector | DECTRIS PILATUS 200K |
Wavelength(s) | 1.54178 |
Spacegroup name | P 6 |
Unit cell lengths | 90.599, 90.599, 45.121 |
Unit cell angles | 90.00, 90.00, 120.00 |
Refinement procedure
Resolution | 40.000 - 1.700 |
R-factor | 0.1539 |
Rwork | 0.152 |
R-free | 0.19210 |
Structure solution method | MOLECULAR REPLACEMENT |
Starting model (for MR) | 2mbw |
RMSD bond length | 0.025 |
RMSD bond angle | 2.418 |
Data reduction software | HKL-3000 |
Phasing software | HKL-3000 |
Refinement software | REFMAC (5.8.0131) |
Data quality characteristics
Overall | Inner shell | Outer shell | |
Low resolution limit [Å] | 50.000 | 50.000 | 1.730 |
High resolution limit [Å] | 1.700 | 4.610 | 1.700 |
Rmerge | 0.064 | 0.023 | 0.474 |
Number of reflections | 23456 | ||
<I/σ(I)> | 9.2 | ||
Completeness [%] | 100.0 | 99.8 | 100 |
Redundancy | 9.1 | 7.5 | 6.2 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | BATCH MODE | 9 | 293 | 100 mM Tris-HCl pH 9.0, 1 mM EDTA, 2.3 M Ammonium sulfate |