5IBW

Complex of MlcC bound to the tandem IQ motif of MyoC

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsCLSI BEAMLINE 08ID-1
Synchrotron siteCLSI
Beamline08ID-1
Temperature [K]100
Detector technologyCCD
Collection date2016-02-12
DetectorMARMOSAIC 300 mm CCD
Wavelength(s)1.7712
Spacegroup nameP 1
Unit cell lengths28.680, 31.410, 56.410
Unit cell angles75.79, 84.00, 67.06
Refinement procedure
Resolution28.200 - 1.900
Rwork0.140
R-free0.19000
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)2ix7
Data reduction softwareXDS
Data scaling softwareXSCALE
Phasing softwarePHASER
Refinement softwarePHENIX
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]28.2001.970
High resolution limit [Å]1.9001.900
Rmerge0.043
Number of reflections12613
<I/σ(I)>26.9
Completeness [%]90.9
Redundancy3.8
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, HANGING DROP5.62980.7M NaH2PO4/K2HPO4 pH 5.6

219869

PDB entries from 2024-05-15