5HZ0
Plant peptide hormone receptor RGFR1 in complex with RGF2
Experimental procedure
Experimental method | LAUE |
Source type | SYNCHROTRON |
Source details | SSRF BEAMLINE BL17U |
Synchrotron site | SSRF |
Beamline | BL17U |
Temperature [K] | 100 |
Detector technology | CCD |
Collection date | 2014-12-21 |
Detector | OXFORD SAPPHIRE CCD |
Wavelength(s) | 1 |
Spacegroup name | H 3 |
Unit cell lengths | 181.000, 181.000, 87.968 |
Unit cell angles | 90.00, 90.00, 120.00 |
Refinement procedure
Resolution | 30.940 - 2.560 |
R-factor | 0.2316 |
Rwork | 0.232 |
Structure solution method | MOLECULAR REPLACEMENT |
Data scaling software | HKL-2000 |
Phasing software | PHENIX |
Refinement software | PHENIX |
Data quality characteristics
Overall | |
Low resolution limit [Å] | 99.000 |
High resolution limit [Å] | 2.550 |
Number of reflections | 33781 |
<I/σ(I)> | 14.5 |
Completeness [%] | 96.9 |
Redundancy | 5.4 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, HANGING DROP | 293 | 0.1M MES monohydrate pH 6.0, 22%(v/v) polyethylene glycol (PEG) 400. |