5HXG
STM1697-FlhD complex
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | SSRF BEAMLINE BL17U |
Synchrotron site | SSRF |
Beamline | BL17U |
Temperature [K] | 100 |
Detector technology | CCD |
Collection date | 2014-03-10 |
Detector | ADSC QUANTUM 315r |
Wavelength(s) | 0.979 |
Spacegroup name | P 31 |
Unit cell lengths | 61.006, 61.006, 166.891 |
Unit cell angles | 90.00, 90.00, 120.00 |
Refinement procedure
Resolution | 38.309 - 1.998 |
R-factor | 0.1791 |
Rwork | 0.178 |
R-free | 0.20610 |
Structure solution method | MOLECULAR REPLACEMENT |
RMSD bond length | 0.007 |
RMSD bond angle | 0.832 |
Data reduction software | HKL-2000 |
Data scaling software | HKL-2000 |
Phasing software | HKL-2000 |
Refinement software | PHENIX ((1.10_2155: ???)) |
Data quality characteristics
Overall | |
Low resolution limit [Å] | 50.000 |
High resolution limit [Å] | 1.998 |
Number of reflections | 47026 |
<I/σ(I)> | 23.11 |
Completeness [%] | 97.0 |
Redundancy | 5.6 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | EVAPORATION | 291 | 0.2M KCl, 0.01M MgCl2, 0.05M MES pH5.6, 5% PEG 8000 |