5HEU

Pentameric ligand-gated ion channel ELIC mutant A257Y

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsSLS BEAMLINE X06SA
Synchrotron siteSLS
BeamlineX06SA
Temperature [K]100
Detector technologyPIXEL
Collection date2013-07-14
DetectorDECTRIS PILATUS 6M
Wavelength(s)0.978
Spacegroup nameP 1 21 1
Unit cell lengths105.000, 266.610, 110.710
Unit cell angles90.00, 110.47, 90.00
Refinement procedure
Resolution29.939 - 3.200
R-factor0.2211
Rwork0.220
R-free0.24670
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)2yn6
RMSD bond length0.003
RMSD bond angle0.584
Data reduction softwareXDS
Data scaling softwareXDS
Phasing softwarePHASER
Refinement softwarePHENIX ((1.10_2155: ???))
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]50.0003.300
High resolution limit [Å]3.2003.200
Rmerge0.0850.740
Number of reflections93158
<I/σ(I)>15.22.3
Completeness [%]99.399.2
Redundancy3.93.8
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, SITTING DROP6.5277PEG 4000, ammonium sulfate

219869