5HEU
Pentameric ligand-gated ion channel ELIC mutant A257Y
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | SLS BEAMLINE X06SA |
Synchrotron site | SLS |
Beamline | X06SA |
Temperature [K] | 100 |
Detector technology | PIXEL |
Collection date | 2013-07-14 |
Detector | DECTRIS PILATUS 6M |
Wavelength(s) | 0.978 |
Spacegroup name | P 1 21 1 |
Unit cell lengths | 105.000, 266.610, 110.710 |
Unit cell angles | 90.00, 110.47, 90.00 |
Refinement procedure
Resolution | 29.939 - 3.200 |
R-factor | 0.2211 |
Rwork | 0.220 |
R-free | 0.24670 |
Structure solution method | MOLECULAR REPLACEMENT |
Starting model (for MR) | 2yn6 |
RMSD bond length | 0.003 |
RMSD bond angle | 0.584 |
Data reduction software | XDS |
Data scaling software | XDS |
Phasing software | PHASER |
Refinement software | PHENIX ((1.10_2155: ???)) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 50.000 | 3.300 |
High resolution limit [Å] | 3.200 | 3.200 |
Rmerge | 0.085 | 0.740 |
Number of reflections | 93158 | |
<I/σ(I)> | 15.2 | 2.3 |
Completeness [%] | 99.3 | 99.2 |
Redundancy | 3.9 | 3.8 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, SITTING DROP | 6.5 | 277 | PEG 4000, ammonium sulfate |