5HEJ
Pentameric ligand-gated ion channel ELIC mutant F116A
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | SLS BEAMLINE X06DA |
Synchrotron site | SLS |
Beamline | X06DA |
Temperature [K] | 100 |
Detector technology | PIXEL |
Collection date | 2012-02-28 |
Detector | DECTRIS PILATUS 6M |
Wavelength(s) | 0.980 |
Spacegroup name | P 1 21 1 |
Unit cell lengths | 105.168, 266.994, 111.002 |
Unit cell angles | 90.00, 110.25, 90.00 |
Refinement procedure
Resolution | 29.999 - 3.500 |
R-factor | 0.2155 |
Rwork | 0.213 |
R-free | 0.25450 |
RMSD bond length | 0.002 |
RMSD bond angle | 0.543 |
Data reduction software | XDS |
Data scaling software | XDS |
Phasing software | PHASER |
Refinement software | PHENIX ((1.10_2155: ???)) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 50.000 | 3.600 |
High resolution limit [Å] | 3.500 | 3.500 |
Rmerge | 0.090 | 0.770 |
Number of reflections | 71671 | |
<I/σ(I)> | 14.2 | 2 |
Completeness [%] | 99.4 | |
Redundancy | 3.4 | 3.6 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, SITTING DROP | 6.5 | 277 | PEG 4000, Ammonium sulfate |