5GLH
Human endothelin receptor type-B in complex with ET-1
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | SPRING-8 BEAMLINE BL32XU |
Synchrotron site | SPring-8 |
Beamline | BL32XU |
Temperature [K] | 100 |
Detector technology | CCD |
Collection date | 2013-11-11 |
Detector | RAYONIX MX225HE |
Wavelength(s) | 1.000 |
Spacegroup name | C 2 2 21 |
Unit cell lengths | 72.970, 172.970, 109.350 |
Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
Resolution | 46.214 - 2.800 |
R-factor | 0.2379 |
Rwork | 0.234 |
R-free | 0.27680 |
RMSD bond length | 0.002 |
RMSD bond angle | 0.472 |
Refinement software | PHENIX (1.10_2155) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 50.000 | 2.900 |
High resolution limit [Å] | 2.800 | 2.800 |
Rmerge | 0.154 | 1.496 |
Number of reflections | 17421 | |
<I/σ(I)> | 15.2 | 1.76 |
Completeness [%] | 99.9 | 100 |
Redundancy | 15.2 | 13.8 |
CC(1/2) | 0.999 | 0.975 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | LIPIDIC CUBIC PHASE | 6 | 293 | PEG 400, MES, (NH4)2SO4, 1,4-butanediol |