5FOT
HUMANISED MONOMERIC RADA IN COMPLEX WITH FHTU TETRAPEPTIDE
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | SLS BEAMLINE X06DA |
Synchrotron site | SLS |
Beamline | X06DA |
Temperature [K] | 100 |
Detector technology | CCD |
Collection date | 2009-08-06 |
Detector | MARMOSAIC 225 mm CCD |
Spacegroup name | P 21 21 21 |
Unit cell lengths | 40.220, 60.632, 87.431 |
Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
Resolution | 31.296 - 1.189 |
R-factor | 0.1337 |
Rwork | 0.132 |
R-free | 0.15670 |
Structure solution method | MOLECULAR REPLACEMENT |
Starting model (for MR) | 4b3b |
RMSD bond length | 0.011 |
RMSD bond angle | 1.374 |
Data reduction software | XDS |
Data scaling software | XDS |
Phasing software | AMoRE |
Refinement software | PHENIX ((PHENIX.REFINE)) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 23.300 | 1.260 |
High resolution limit [Å] | 1.190 | 1.190 |
Rmerge | 0.050 | 0.270 |
Number of reflections | 69123 | |
<I/σ(I)> | 14.46 | 2.76 |
Completeness [%] | 90.8 | 65.1 |
Redundancy | 3.22 | 1.77 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | 6.2 | 8% PEG-1000, 100 MM NAK PHOSPHATE, PH 6.2 |