5FNC
Dynamic Undocking and the Quasi-Bound State as tools for Drug Design
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | ROTATING ANODE |
Source details | BRUKER D8 VENTURE TXS GENERATOR |
Temperature [K] | 100 |
Detector technology | CMOS |
Collection date | 2014-12-08 |
Detector | BRUKER PHOTON 100 |
Spacegroup name | I 2 2 2 |
Unit cell lengths | 66.872, 90.285, 98.332 |
Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
Resolution | 20.520 - 2.200 |
R-factor | 0.19358 |
Rwork | 0.191 |
R-free | 0.24039 |
Structure solution method | MOLECULAR REPLACEMENT |
Starting model (for MR) | 2wi6 |
RMSD bond length | 0.018 |
RMSD bond angle | 1.920 |
Data reduction software | SAINT |
Data scaling software | SADABS |
Phasing software | AMoRE |
Refinement software | REFMAC (5.7.0029) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 66.510 | 2.240 |
High resolution limit [Å] | 2.200 | 2.200 |
Rmerge | 0.080 | 0.320 |
Number of reflections | 15401 | |
<I/σ(I)> | 11.17 | 2.94 |
Completeness [%] | 99.5 | 96.3 |
Redundancy | 4.27 | 2.94 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | 6.5 | pH 6.5 |