Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

5FMN

The nickel-responsive transcriptional regulator InrS

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsDIAMOND BEAMLINE I02
Synchrotron siteDiamond
BeamlineI02
Temperature [K]100
Detector technologyPIXEL
DetectorPILATUS
Spacegroup nameI 2 2 2
Unit cell lengths64.290, 77.790, 85.500
Unit cell angles90.00, 90.00, 90.00
Refinement procedure
Resolution57.540 - 2.400
R-factor0.20812
Rwork0.204
R-free0.28231
Structure solution methodOTHER
Starting model (for MR)NONE
RMSD bond length0.011
RMSD bond angle1.398
Data reduction softwareXDS
Data scaling softwareXDS
Refinement softwareREFMAC (5.8.0107)
Data quality characteristics
 Overall
Low resolution limit [Å]60.000
High resolution limit [Å]2.400
Rmerge0.040
Number of reflections8308
<I/σ(I)>27.7
Completeness [%]95.0
Redundancy6.1
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, HANGING DROPHANGING DROP 100+ 100 NL WITH 0.2 M MGCL2, 0.1 TRIS PH 8.5 AND 20% PEG8000

219869

PDB entries from 2024-05-15