5FFC
CopM in the Cu(II)-bound form
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | SSRF BEAMLINE BL17U |
Synchrotron site | SSRF |
Beamline | BL17U |
Temperature [K] | 100 |
Detector technology | CCD |
Collection date | 2015-10-09 |
Detector | ADSC QUANTUM 315r |
Wavelength(s) | 0.9793 |
Spacegroup name | P 1 21 1 |
Unit cell lengths | 32.240, 86.669, 53.431 |
Unit cell angles | 90.00, 92.33, 90.00 |
Refinement procedure
Resolution | 27.097 - 2.007 |
R-factor | 0.2282 |
Rwork | 0.226 |
R-free | 0.26860 |
Structure solution method | MOLECULAR REPLACEMENT |
Starting model (for MR) | 3bt5 |
RMSD bond length | 0.004 |
RMSD bond angle | 0.807 |
Data reduction software | HKL-2000 |
Data scaling software | HKL-2000 |
Phasing software | PHASER |
Refinement software | PHENIX (1.8.1_1168) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 50.000 | 2.070 |
High resolution limit [Å] | 2.000 | 2.000 |
Rmerge | 0.460 | |
Number of reflections | 19161 | |
<I/σ(I)> | 11.9 | 1.9 |
Completeness [%] | 97.9 | 96.6 |
Redundancy | 3.7 | 3.7 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, SITTING DROP | 289 | 0.1M HEPES 7.0, 0.1M Lithium sulphate, 25% PEG 3350 |