Loading
PDBj
MenuPDBj@FacebookPDBj@X(formerly Twitter)PDBj@BlueSkyPDBj@YouTubewwPDB FoundationwwPDBDonate
RCSB PDBPDBeBMRBAdv. SearchSearch help

5FD5

manganese uptake regulator

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsDIAMOND BEAMLINE I24
Synchrotron siteDiamond
BeamlineI24
Temperature [K]100
Detector technologyPIXEL
Collection date2011-12-01
DetectorDECTRIS PILATUS 6M
Wavelength(s)0.9686
Spacegroup nameC 2 2 2
Unit cell lengths163.800, 171.320, 90.220
Unit cell angles90.00, 90.00, 90.00
Refinement procedure
Resolution53.920 - 1.910
R-factor0.22337
Rwork0.222
R-free0.24660
Structure solution methodMOLECULAR REPLACEMENT
RMSD bond length0.006
RMSD bond angle1.101
Data reduction softwarexia2
Data scaling softwarexia2
Phasing softwareMOLREP
Refinement softwareREFMAC (5.6.0117)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]54.000
High resolution limit [Å]1.9101.910
Rmerge0.0360.540
Number of reflections97820
<I/σ(I)>29.62.2
Completeness [%]99.799.9
Redundancy4.4
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, SITTING DROP2930.1 M sodium acetate pH 4.75, 0.8 M ammonium sulfate and 2 M NaCl

229380

PDB entries from 2024-12-25

PDB statisticsPDBj update infoContact PDBjnumon