Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

5F0N

Cohesin subunit Pds5

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsESRF BEAMLINE ID23-1
Synchrotron siteESRF
BeamlineID23-1
Temperature [K]100
Detector technologyPIXEL
Collection date2015-06-28
DetectorDECTRIS PILATUS 6M-F
Wavelength(s)0.9796
Spacegroup nameH 3
Unit cell lengths238.210, 238.210, 80.660
Unit cell angles90.00, 90.00, 120.00
Refinement procedure
Resolution46.667 - 3.200
R-factor0.2392
Rwork0.236
R-free0.29510
Structure solution methodMOLECULAR REPLACEMENT
RMSD bond length0.003
RMSD bond angle0.726
Data reduction softwareXDS
Data scaling softwareSCALA
Phasing softwarePHASER
Refinement softwarePHENIX
Data quality characteristics
 Overall
Low resolution limit [Å]46.670
High resolution limit [Å]3.200
Rmerge0.109
Number of reflections28140
<I/σ(I)>14.5
Completeness [%]100.0
Redundancy10.5
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, SITTING DROP7.5293100 mM HEPES pH 7.5, and 1.3-1.6 M lithium sulphate

219869

PDB entries from 2024-05-15

PDB statisticsPDBj update infoContact PDBjnumon