5EFV
The host-recognition device of Staphylococcus aureus phage Phi11
Experimental procedure
| Experimental method | SINGLE WAVELENGTH |
| Source type | SYNCHROTRON |
| Source details | SLS BEAMLINE X06SA |
| Synchrotron site | SLS |
| Beamline | X06SA |
| Temperature [K] | 80 |
| Detector technology | PIXEL |
| Collection date | 2014-03-08 |
| Detector | PSI PILATUS 6M |
| Wavelength(s) | 1 |
| Spacegroup name | P 1 |
| Unit cell lengths | 87.060, 89.010, 93.260 |
| Unit cell angles | 93.02, 105.25, 117.58 |
Refinement procedure
| Resolution | 44.400 - 2.200 |
| R-factor | 0.1749 |
| Rwork | 0.173 |
| R-free | 0.21060 |
| Structure solution method | MAD |
| RMSD bond length | 0.010 |
| RMSD bond angle | 1.120 |
| Data reduction software | XDS |
| Data scaling software | XDS |
| Phasing software | SHARP |
| Refinement software | BUSTER (2.10.2) |
Data quality characteristics
| Overall | Outer shell | |
| Low resolution limit [Å] | 44.400 | 2.279 |
| High resolution limit [Å] | 2.200 | 2.200 |
| Number of reflections | 116564 | |
| <I/σ(I)> | 14.9 | |
| Completeness [%] | 97.8 | 97 |
| Redundancy | 3.6 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 | VAPOR DIFFUSION, HANGING DROP | 289 | PEG, sugar-mix, Tris |