5E8U
TGF-BETA RECEPTOR TYPE 1 KINASE DOMAIN (T204D,I211V,Y249F,S280T, Y282F,S287N,A350C,L352F)
Experimental procedure
| Experimental method | SINGLE WAVELENGTH |
| Source type | SYNCHROTRON |
| Source details | CLSI BEAMLINE 08ID-1 |
| Synchrotron site | CLSI |
| Beamline | 08ID-1 |
| Temperature [K] | 100 |
| Detector technology | CCD |
| Collection date | 2014-09-20 |
| Detector | RAYONIX MX-300 |
| Wavelength(s) | 0.980 |
| Spacegroup name | P 21 21 21 |
| Unit cell lengths | 41.600, 77.100, 89.600 |
| Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
| Resolution | 44.800 - 2.030 |
| R-factor | 0.1815 |
| Rwork | 0.179 |
| R-free | 0.22280 |
| Structure solution method | MOLECULAR REPLACEMENT |
| Starting model (for MR) | 3tzm |
| RMSD bond length | 0.010 |
| RMSD bond angle | 1.010 |
| Data reduction software | HKL-2000 |
| Data scaling software | HKL-2000 |
| Phasing software | AMoRE |
| Refinement software | BUSTER-TNT (BUSTER 2.11.6) |
Data quality characteristics
| Overall | Outer shell | |
| Low resolution limit [Å] | 50.000 | 2.080 |
| High resolution limit [Å] | 2.010 | 2.010 |
| Rmerge | 0.470 | |
| Number of reflections | 19168 | |
| <I/σ(I)> | 13.9 | 3 |
| Completeness [%] | 99.9 | 99.4 |
| Redundancy | 4.7 | 4.6 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 | VAPOR DIFFUSION, HANGING DROP | 5.6 | 277 | 23%(w/v) PEG3350, 3%(v/v) glcyerol |