Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

5E62

HEF-mut with Tr323 complex

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsSSRF BEAMLINE BL17U
Synchrotron siteSSRF
BeamlineBL17U
Temperature [K]100
Detector technologyCCD
Collection date2014-08-02
DetectorADSC QUANTUM 315
Wavelength(s)1
Spacegroup nameP 21 3
Unit cell lengths164.825, 164.825, 164.825
Unit cell angles90.00, 90.00, 90.00
Refinement procedure
Resolution49.697 - 2.203
R-factor0.2064
Rwork0.204
R-free0.24420
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)1flc
RMSD bond length0.010
RMSD bond angle1.501
Data reduction softwareHKL-2000
Data scaling softwareHKL-2000
Phasing softwarePHASER
Refinement softwarePHENIX ((phenix.refine: 1.9_1692))
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]50.0002.280
High resolution limit [Å]2.2002.200
Rmerge0.0930.565
Number of reflections75303
<I/σ(I)>25.25
Completeness [%]100.0100
Redundancy9.79.7
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, SITTING DROP2910.1M PCTP (Propionic acid, Cacodylate, Bis-tris propane system) buffer pH 8.5, 22.5%(w/v) PEG1500

219869

PDB entries from 2024-05-15

PDB statisticsPDBj update infoContact PDBjnumon