5E62
HEF-mut with Tr323 complex
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | SSRF BEAMLINE BL17U |
Synchrotron site | SSRF |
Beamline | BL17U |
Temperature [K] | 100 |
Detector technology | CCD |
Collection date | 2014-08-02 |
Detector | ADSC QUANTUM 315 |
Wavelength(s) | 1 |
Spacegroup name | P 21 3 |
Unit cell lengths | 164.825, 164.825, 164.825 |
Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
Resolution | 49.697 - 2.203 |
R-factor | 0.2064 |
Rwork | 0.204 |
R-free | 0.24420 |
Structure solution method | MOLECULAR REPLACEMENT |
Starting model (for MR) | 1flc |
RMSD bond length | 0.010 |
RMSD bond angle | 1.501 |
Data reduction software | HKL-2000 |
Data scaling software | HKL-2000 |
Phasing software | PHASER |
Refinement software | PHENIX ((phenix.refine: 1.9_1692)) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 50.000 | 2.280 |
High resolution limit [Å] | 2.200 | 2.200 |
Rmerge | 0.093 | 0.565 |
Number of reflections | 75303 | |
<I/σ(I)> | 25.2 | 5 |
Completeness [%] | 100.0 | 100 |
Redundancy | 9.7 | 9.7 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, SITTING DROP | 291 | 0.1M PCTP (Propionic acid, Cacodylate, Bis-tris propane system) buffer pH 8.5, 22.5%(w/v) PEG1500 |