HIV-1 Rev NTD dimers with variable crossing angles

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsDIAMOND BEAMLINE I24
Synchrotron siteDiamond
BeamlineI24
Temperature [K]80
Detector technologyPIXEL
Collection date2010-07-01
DetectorPSI PILATUS 6M
Wavelength(s)0.9779
Spacegroup nameP 1 21 1
Unit cell lengths43.895, 81.869, 98.809
Unit cell angles90.00, 101.09, 90.00
Refinement procedure
Resolution20.280 - 2.300
R-factor0.1897
Rwork0.188
R-free0.22690
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)3X7L
RMSD bond length0.010
RMSD bond angle1.150
Data scaling softwareHKL-2000
Phasing softwarePHASER
Refinement softwareBUSTER (2.9.2)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]48.5002.400
High resolution limit [Å]2.3002.300
Rmerge0.846
Number of reflections30611
<I/σ(I)>11.51.6
Completeness [%]100.0100
Redundancy8.15
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, SITTING DROP293Crystals of scFv-Rev were initially grown in 20% PEG 3350, a variety of salts (200 mM sodium sulfate, sodium bromide, or ammonium phosphate dibasic), and pH ranging from 6.5-8.5.