5CC0
AncSR2 - TSLP nGRE complex
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | APS BEAMLINE 22-ID |
Synchrotron site | APS |
Beamline | 22-ID |
Temperature [K] | 100 |
Detector technology | CCD |
Collection date | 2012-03-12 |
Detector | MARMOSAIC 300 mm CCD |
Wavelength(s) | 1.00 |
Spacegroup name | P 21 21 21 |
Unit cell lengths | 50.334, 72.507, 104.942 |
Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
Resolution | 38.469 - 2.405 |
R-factor | 0.2166 |
Rwork | 0.214 |
R-free | 0.23720 |
RMSD bond length | 0.013 |
RMSD bond angle | 1.619 |
Data reduction software | HKL-2000 |
Phasing software | PHASER |
Refinement software | PHENIX (1.9_1692) |
Data quality characteristics
Overall | |
Low resolution limit [Å] | 45.000 |
High resolution limit [Å] | 2.400 |
Number of reflections | 15335 |
<I/σ(I)> | 34.5 |
Completeness [%] | 99.8 |
Redundancy | 8.3 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, HANGING DROP | 298 | in 0.1 M HEPES (pH 7.5), 10% PEG 20000, 5% glycerol, 5% ethanol |