Loading
PDBj
MenuPDBj@FacebookPDBj@X(formerly Twitter)PDBj@BlueSkyPDBj@YouTubewwPDB FoundationwwPDBDonate
RCSB PDBPDBeBMRBAdv. SearchSearch help

5C4K

APH(2")-IVa in complex with GET (G418) at room temperature

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsESRF BEAMLINE BM30A
Synchrotron siteESRF
BeamlineBM30A
Temperature [K]291.15
Detector technologyCCD
Collection date2015-05-07
DetectorADSC QUANTUM 315r
Wavelength(s)0.9797
Spacegroup nameP 1 21 1
Unit cell lengths78.703, 64.941, 78.870
Unit cell angles90.00, 90.73, 90.00
Refinement procedure
Resolution78.860 - 3.050
R-factor0.1612
Rwork0.159
R-free0.19920
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)4n57
RMSD bond length0.012
RMSD bond angle1.515
Data reduction softwareXDS
Data scaling softwareSCALA
Refinement softwareREFMAC (5.8.0073)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]42.4403.050
High resolution limit [Å]2.9002.900
Rmerge0.0870.529
Number of reflections16269
<I/σ(I)>2.61.4
Completeness [%]90.493.4
Redundancy1.61.5
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, SITTING DROP7.4291.1512% PEG3350, 50-90 mM Ammonium citrate

245663

PDB entries from 2025-12-03

PDB statisticsPDBj update infoContact PDBjnumon