5AWW
Precise Resting State of Thermus thermophilus SecYEG
Experimental procedure
| Experimental method | SINGLE WAVELENGTH |
| Source type | SYNCHROTRON |
| Source details | SPRING-8 BEAMLINE BL32XU |
| Synchrotron site | SPring-8 |
| Beamline | BL32XU |
| Temperature [K] | 100 |
| Detector technology | CCD |
| Collection date | 2015-01-20 |
| Detector | RAYONIX MX225HE |
| Wavelength(s) | 1.0 |
| Spacegroup name | I 2 2 2 |
| Unit cell lengths | 105.493, 112.904, 140.002 |
| Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
| Resolution | 43.943 - 2.724 |
| R-factor | 0.2234 |
| Rwork | 0.219 |
| R-free | 0.26830 |
| Structure solution method | MOLECULAR REPLACEMENT |
| Starting model (for MR) | 2zjs |
| RMSD bond length | 0.003 |
| RMSD bond angle | 0.623 |
| Data scaling software | SCALEPACK |
| Phasing software | PHASER |
| Refinement software | PHENIX ((phenix.refine: 1.9_1692)) |
Data quality characteristics
| Overall | |
| Low resolution limit [Å] | 50.000 |
| High resolution limit [Å] | 2.700 |
| Number of reflections | 21452 |
| <I/σ(I)> | 10.5 |
| Completeness [%] | 94.5 |
| Redundancy | 4.7 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 | LIPIDIC CUBIC PHASE | 6.5 | 293 | PEG 500MME, MgSO4, Na2SO4 |