Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

5AWW

Precise Resting State of Thermus thermophilus SecYEG

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsSPRING-8 BEAMLINE BL32XU
Synchrotron siteSPring-8
BeamlineBL32XU
Temperature [K]100
Detector technologyCCD
Collection date2015-01-20
DetectorRAYONIX MX225HE
Wavelength(s)1.0
Spacegroup nameI 2 2 2
Unit cell lengths105.493, 112.904, 140.002
Unit cell angles90.00, 90.00, 90.00
Refinement procedure
Resolution43.943 - 2.724
R-factor0.2234
Rwork0.219
R-free0.26830
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)2zjs
RMSD bond length0.003
RMSD bond angle0.623
Data scaling softwareSCALEPACK
Phasing softwarePHASER
Refinement softwarePHENIX ((phenix.refine: 1.9_1692))
Data quality characteristics
 Overall
Low resolution limit [Å]50.000
High resolution limit [Å]2.700
Number of reflections21452
<I/σ(I)>10.5
Completeness [%]94.5
Redundancy4.7
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1LIPIDIC CUBIC PHASE6.5293PEG 500MME, MgSO4, Na2SO4

219869

PDB entries from 2024-05-15

PDB statisticsPDBj update infoContact PDBjnumon