4Q1R
Galectin-1 in Complex with Ligand AN027
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | ESRF BEAMLINE ID23-1 |
Synchrotron site | ESRF |
Beamline | ID23-1 |
Temperature [K] | 100 |
Detector technology | PIXEL |
Detector | DECTRIS PILATUS 6M-F |
Wavelength(s) | 0.9764 |
Spacegroup name | P 21 21 21 |
Unit cell lengths | 43.140, 58.410, 111.170 |
Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
Resolution | 51.707 - 1.470 |
R-factor | 0.1561 |
Rwork | 0.154 |
R-free | 0.19390 |
Structure solution method | MOLECULAR REPLACEMENT |
RMSD bond length | 0.011 |
RMSD bond angle | 1.546 |
Data reduction software | XDS |
Data scaling software | XDS |
Phasing software | PHASER |
Refinement software | PHENIX ((phenix.refine: 1.8.2_1309)) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 51.707 | |
High resolution limit [Å] | 1.470 | 1.470 |
Number of reflections | 48330 | |
<I/σ(I)> | 15.8 | |
Completeness [%] | 99.3 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, HANGING DROP | 7.5 | 289 | ammonium sulfate, pH 7.5, VAPOR DIFFUSION, HANGING DROP, temperature 289K |